Needle Incinerator(Needle & Syringe Destroyers) and Micro Incinerator for COVID 19 waste





Email: [email protected]
2020-07-21





2020-07-21
* Burning Rate (50-120kg/hour) * Minimum Operating Temperature (850°ϲ(Primary combustion) * Maximum Operating Temperature (1450°ϲ(Afterburner chamber) * Secondary Burning Capacity (Compulsory) * Density Insulation (20mm high) * Refractory Casting (Minimum 65mm) * Heavy duty refracting lining to withstand (1500°ϲ) * Average burn out time: Maximum (3.0 hours) * Fuel Type (Diesel) * Fuel Consumption in L/hr: (7.5 to 9) * Residence time in secondary chamber (2 sec.) * Residue ash post 100kg (Max. 3.8kg) * Installation period (Maximum 7days) Type : Refractory constructions Steel Structure 400+ Silica board + Fire Brick and Castable between Size : Outside – W 740 x L 1112 x H 790 / Inside – W 400 x L 800 x H 560 (mm) Fire load of Combustion volume : 0.18 m3 Fire table area : 0.32 m2 Material : SS400 x 6.0T, Silica Board, Fire Brick (SK-36), Castable (HACT-160) Temperature : 700 ~ 900 ℃ Residual gas combustion in secondary chambers : ≥ 2sec Input door size : W 200 x H 200 (mm) Ash door size : W 300 x H 400 (mm) Type : Refractory constructions Steel Structure 400+ Silica board + Fire Brick and Castable between Size : Outside – W 740 x L 1112 x H 745 / Inside – W 400 x L 800 x H 600 (mm) Fire load of Combustion volume : 0.19 m3 Fire table area : 0.32 m2 Material : SS400 x 6.0T, Silica Board 50T, Fire Brick (SK-36), Castable (HACT-160) Temperature : 1000 ~ 1100 ℃ WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat) Website: www.hiclover.com Email: [email protected] Email: [email protected] Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour…
Size: 940 x860x2700 mm Material: STAINLESS STEEL STACK, REFRACTORY CONCRETE LINING SPECIAL INSULATION MATERIAL With burner: 15 C 20 KW Temperature: PRIMARY CHAMBER = 800°C AND SECONDARY CHAMBER = 850 – 1200° C Sufficient heat generation for secure and complete combustion 600-800 °C in the first chamber and >1000 °C in the second chamber Easy transportation on standard EURO-pallets Constructed in a modular fashion easy on-site movement and assembly with a minimum of equipment and technical skills; For the destruction of problematic waste like sharps, amputates and body parts, wet or moist matter; Off-gas quality: moderate smoke emissions during one quarter of the total incineration time; no visible emission during three quarters. AS PER INTERNATIONAL STANDARDS The remaining ash approximately 5-10% in weight and below 1% in volume of the original waste AS PER INTERNATIONAL STANDARDS Chimney height at least 5 m above the incinerator 5m ABOVE FROM THE GROUND Temperature resistance of the lining at least 1,200 °C
“Their engineers usually go out to help with installation but as a result of the Ebola threat, engineers employed by aid organisations and agencies are being sent to be trained up at the plant in Canning Road Industrial Estate rather than Mr Niklas added:”They contacted us when the outbreak started a few months ago. But…
Operating period Anticipated daily period 8 hours Maximum operating period 12hours Chamber Should be refractory lined to the following standards, hearth and lower section of chamber walls. Hot face materials Super dusty firebricks Limiting continuous service limit 1500°c Thickness 100mm Thermal conductivity 1.3W/mk Insulation Calcium silicate Limiting continuous service limit 1000°c Thickness 25mm Thermal conductivity 0.095w/mk Chimney/stack Should be manufactured from refractory lined mild steel or high quality air cooled stainless steel. The chimney/stack should have a minimum height of 10 meters above ground level Ignition burners Fully packed oil type complete with electric ignition and flame failure controls wired with continuous running fan and complete with all valves, fan and motor Maximum rating : at least 450kw/hour Burner: arranged for on/off operation Maximum consumption : at least 6litres per hour Average consumption : at least 3litres/hour After burner Fully packed oil type complete with electric ignition and flame failure controls wired with continuous running fan and complete with all valves fan and motor. Maximum rating : At least 450kw/hour Burner: arranged for on/off operation Maximum consumption: at least 9 litres/hour Average consumption: at least 4.5 litres /hour Flue gas treatment Should have particulate remover (scrubbers) Electrical supply Single phase 220/240v a.c,50/60hz Documentation Operation manual 2 sets Service /maintenance manual 2 sets
معلومات أساسية. نموذج رقم: مصنعي محارق البرسيم في الصين أسواق التصدير: عالمية وصف المنتج Nanjing Clover Medical Technology Co.، Ltd. ، يقع في مدينة نانجينغ ، الصين. CLOVER هي الشركة المصنعة للمنتجات الطبية ومحرقة النفايات وأفران حرق جثث حيوانات المزرعة الأخرى ، ومحرقة كريماتوتيوم الخاصة بمعدات حيوانات المزرعة ، ومحرقة حيوانات المزرعة ، ومحرقة التصفية…
Базовая информация. Номер модели: инсинератор для домашних животных для продажи Экспортные рынки: глобальный описание продукта Компания Nanjing Clover Medical Technology Co., Ltd. является ведущим производителем мусоросжигательных установок в Китае. Мы – местный производитель и один из крупнейших экспортеров Китая. Техническое оборудование пиролитических инсинераторов – это основная обработка отходов во всем мире, включая медицинские отходы, сжигание…