Oil Pump Suction Line and Return Line on incinerator burner
on incinerator burner, there’s 1 oil pump and have two tube for Suction Line and Return Line.
Basic Info. Model NO.:smokeless crematorium Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Product Description Items Specification Model TS10(PLC) / TS20(PLC) / TS30(PLC) / TS50(PLC) / TS100(PLC) Main Product List Double Combustion Chamber Smoke Filter Chamber PLC Mode Control Case Stainless Steel Chimney Italy oil/gas burner: 02 units Oil Tank (if oil fuel)
Basic Info. Export Markets:Global Additional Info. Trademark:clover Product Description Pyrolytic incineration specialized is conventional waste treatment way for several decades. All over the planet, in many nations, individuals anti incinerator because the incinerator will produce a sizable Dioxin from the smoke. Dioxins could be released into the environment through forest fires, low price vinyl incinerator…
All kindly pets owners hope their lovely dog or cat be in heaven after they leave us. We understand the special bond between pet and owner and believe that it should never be forgotten. Losing a pet can be devastating and we built our business so families can remember their pets forever. the range of…
Medical Waste Incinerator, 50 to 60 Kg/hr Support Health Sector Support Project Point of Installation (Hospitals) Moi Voi, Makindu, Maragua, Eldama Ravine and Isiolo District Hospitals 1. General Description Supply, delivery, installation and commissioning of a medical waste incinerator suitable for disposal of Medical, General and Pathological waste in a safe and clean environment. The unit shall consist of two chambers and operate on the principal of controlled air and temperature. The unit shall consist a particulate remover (scrubbers) as stipulated in waste management regulations, 2006 (Legal notice NO. 121 of 29th September, 2006). The Unit shall be fully automatic and controlled by an automatic electronic controlled system except loading system which shall be manual. The unit shall be capable of incinerating between 50 to 60 kg of solid medical waste per hour. It shall be constructed from mild or aluminized steel lined with refractory material. Main unit Application For incineration, general and pathological Capacity 50 C 60 kg/h burn rate Type Two combustion chambers type; primary and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unit Operating time Minimum 8 hours daily Operating temperature From 850 0C to 1200 0C, Automatic controlled Residual Ash 5 to 10% 3.2 Primary Chamber Construction Constructed from heavy duty mild or aluminized steel Or equal and approved equivalent Insulation material Refractory material lining similar or equal to calcium Silicate and hot face combination of heavy duty brickwork Internal Construction Fixed hearth type complete with gratings, concave bottom and charging door, lined with refractory material Charging Door Suitable for manual loading of wastes and with smooth Dear seal equivalent of Ceramic seals with hinges. Door Lock Automatic, Electric type Ash removal door Provided, for removing resultant bottom ash leftovers from the Primary chamber Gratings Provided Loading Manual loading of waste Primary Burner Fully automatic, with fuel, temperature and speed controls with ignition system, flame detector, Air fan complete with safety features, flame failure, Diesel fired fuel injector type and Flange mounted Blower Provided. For supplying excess combustion air through the distribution system with speed control system Temperature Minimum exit 850 0C Observation port To be provided with protective glass type Construction Constructed from heavy duty mild or aluminized steel or equal and approved equivalent Insulation Refractory material lining Combustion Temperatures Above 850 0C, controlled electronically…
Базовая информация. Источники очистки: переработка твердых отходов Методы обработки: сжигание Экспортные рынки: глобальный Дополнительная информация. Торговая марка: нанкинский клевер. Происхождение: Нанкин описание продукта Компания Nanjing Clover Medical Technology Co., Ltd. является ведущим производителем мусоросжигательных установок в Китае. Мы – местный производитель и один из крупнейших экспортеров Китая. Техническое оборудование пиролитических инсинераторов является основной обработкой отходов…
Incinerator Rated Capacity: 100/KG/Hr Type of Design: Double Chambered Mode of Heating: Heating Elements Primary Combustion Chamber Waste Charging Door: Provided with refractory lining with sealing gaskets Ash Removed Door: Provided with refractory lining with sealing gaskets Outer Body MOC: Mild Steel, 5mm Primary Chamber: Stainless Steel Operating Temperature :800. ± 50◦C Insulation: Insulation Brick Heating Elements Type: Kanthal Al Grade Power Consumption: 75 KW ( Initial Load ) Electrical Supply :3 Phase 440 Volt Control Panel MOC: Mild Steel Power Coated No. of Temp: Controllers : 2 Nos Details: The Control Panel will be provided with contract as relays , switches , indicators etc . Operative on 3 phase. I.D.Fan Type: Centrifugal Type MOC: Mild Steel Capacity:2 HP/3Phase Make of Motor: Kirloskar /Havells/Crompton Combustion Air Fan Type: Centrifugal Type Capacity: 1HP/3Phase Make of Motor: Kirloskar /Havells/Crompton Stack: Type: Wire Supported MOC: Mild Steel of ISstd Height :3 Meters or more